Brands |
N/A HART® Pyromation® |
Configuration Code |
N/A TM01 |
Transmitter Type |
N/A
Code T72-00 Description - (4 to 20) mA isolated programmable HART® transmitter Code T72-D10 Description - (4 to 20) mA isolated programmable HART® transmitter with digital display Code 36T72-D10 Description - (4 to 20) mA isolated programmable HART® transmitter with digital display and general purpose aluminum housing with glass window Code 79T72A-D10 Description - (4 to 20) mA isolated remote mount programmable HART® transmitter with digital display: aluminum housing with glass window. Intrinsic Safety: Ex ia [ia Ga] IIC Gb; Class I, Zone 1, AEx ia [ia Ga] IIC T6...T4 Gb; Class I, Division 2, Groups A,B,C,D T6...T4 - NIFW; Class I, Division 2, Groups A,B,C,D;T6…T4 – NIFW and Associated Apparatus for Class I, Division 1, Groups A,B,C,D Code 79T72B-D10 Description - (4 to 20) mA isolated remote mount programmable HART® transmitter with digital display: Explosion-proof, Dust Ignitionproof aluminum housing with glass window. Class I, Division 1, Groups A,B,C,D; Class II, Division 1 Groups E,F,G; Class III |
Configuration Input |
N/A Code 00 - Unconfigured (Default setting for unconfigured transmitter is 4-wire Pt100 (0 - 100) ºC.) Code 1 - Thermocouple (TC) Code 2 - Resistance Temperature Detectors (RTD) (2-Wire) Code 3 - Resistance Temperature Detectors (RTD) (3-Wire) Code 4 - Resistance Temperature Detectors (RTD) (4-Wire) |
Sensor Input |
N/A Code 55 - 500 Ohm Platinum (α = 0.003 85 ºC-1) Code 85 - 100 Ohm Platinum (α = 0.003 85 ºC-1) Code 95 - 1000 Ohm Platinum (α = 0.003 85 ºC-1) Code B - Type B Thermocouple Code E - Type E Thermocouple Code J - Type J Thermocouple Code K - Type K Thermocouple Code mV - Millivolts Code N - Type N Thermocouple Code R - Type R Thermocouple Code S - Type S Thermocouple Code T - Type T Thermocouple Code W - Resistance |
Fault Condition |
N/A Code D - Downscale Burnout = ≤ 3.6 mA Code U - Upscale Burnout = ≥ 21.0 mA |
Range |
N/A Code S - (Lower Limit – Upper Limit) |
Unit of Measure |
N/A Code C - Celsius Code F - Fahrenheit |
Options |
N/A Code B - Bluetooth® (APP) Configuration (Bluetooth® interface is only active if display is not attached.) |
Accessories |
N/A Code 10303 - Communication Cable Code 10307 - 35 mm Din-rail Mounting Clip Code 22808 - Wall Mount Bracket (Option 79 Only) Code 22809 - Pipe Mount Bracket (Option 79 Only) |
Additional Information |
N/A
These small units can be mounted in Pyromation DIN (Form B) connection heads, or they can be used for surface mounting using a 35 mm DIN-rail mounting clip.
|