Brands |
N/A Pyromation® |
Thermocouple Handle Type |
N/A Code RBF185PGH3 - Heavy-Duty Handle Code RBF185PGL2 - Light-Duty Handle Code RBF185PGM2 - Medium-Duty Handle Code RBF185PGM3 - Medium-Duty Handle Code RBF285PGH3 - Heavy-Duty Handle |
Thermocouple Tolerance |
N/A Code RBF185PGH3 - Class B inCode RBF185PGL2 - Class B inCode RBF185PGM2 - Class B inCode RBF185PGM3 - Class B inCode RBF285PGH3 - Class B in |
Thermocouple Tip Diameter |
N/A Code RBF185PGH3 - 0.180 inCode RBF185PGL2 - 0.134 inCode RBF185PGM2 - 0.134 inCode RBF185PGM3 - 0.180 inCode RBF285PGH3 - 0.180 in |
Thermocouple Grip Diameter |
N/A Code RBF185PGH3 - 3/8 inCode RBF185PGL2 - 1/4 inCode RBF185PGM2 - 5/16 inCode RBF185PGM3 - 5/16 inCode RBF285PGH3 - 3/8 in |
Thermocouple Grip "G" Dimension |
N/A Code RBF185PGH3 - 2-3/8 inCode RBF185PGL2 - 1-1/4 inCode RBF185PGM2 - 2-3/8 inCode RBF185PGM3 - 2-3/8 inCode RBF285PGH3 - 2-3/8 in |
Note for Tolerance |
N/A Refer to RTD tolerance information in the General Information section for calculations to determine specific tolerance at temperature. |
Immersion "U" Length |
N/A Specify "U" dimension in inches using 2 digits, plus any fractional lengths. Examples: 02 = 2", 02(1/2) = 2.5". 12" maximum insertion length. |
Extension Leadwire |
N/A
Code M3 (Insert 3 digit "B" dimension in inches) (Not available with Type K.) - Fluoropolymer Insulation - Stranded Conductor - Stainless Steel Overbraid Fluorinated Ethylene Propylene (FEP) Insulation Code S3 (Insert 3 digit "B" dimension in inches) (Only available in single 3-wire RTD.) - Fluoropolymer Insulation - Stranded Conductor - Silicon Rubber Jacket Code T3 (Insert 3 digit "B" dimension in inches) - Fluoropolymer Insulation - Stranded Conductor Code T3A (Insert 3 digit "B" dimension in inches) - Fluoropolymer Insulation - Stranded Conductor - Flexible Armor Code T3P (Insert 3 digit "B" dimension in inches) - Fluoropolymer Insulation - Stranded Conductor - Flexible Armor - Polyvinyl Chloride (PVC) Coated Code T3T (Insert 3 digit "B" dimension in inches) - Fluoropolymer Insulation - Stranded Conductor - Flexible Armor - Fluorinated Ethylene Propylene (FEP) coated |
Temperature Rating |
N/A Code M3 - 204 ºCCode S3 - 204 ºCCode T3 - 204 ºCCode T3A - 204 ºCCode T3P - 105 ºCCode T3T - 204 ºCCode M3 - 400 ºFCode S3 - 400 ºFCode T3 - 400 ºFCode T3A - 400 ºFCode T3P - 221 ºFCode T3T - 400 ºF |
Terminations |
N/A Code 2 - 2 in. split leads 1/4 in. stripped Code 3 - 2 in. split leads with spade lugs Code 4 - Standard plug Code 6 - Miniature plug |