COMPANY HEADER
The Pyromation thermostat temperature sensors are provided with the sensor, or the sensor and a (4 to 20) mA temperature transmitter, mounted on a sub plate within a standard size thermostat housing. The thermostat housing measures 2-3/4" h x 4-1/2" w x 1-5/8" d and can be mounted either horizontally or vertically on a 2" x 4" electrical hand box. The cover is vented on two sides to provide for airflow over the sensing element, regardless of mounting position. The standard temperature sensing elements are available as a fluoropolymer insulated thermocouple or a three-wire Resistance Temperature Detector (RTD). Matching transmitters are available for all configurations and output ranges.
Request Information
Unit of Measure
Items
SP07 Thermostat Temperature Sensors

SP07 2-3/4 Inch (in) Thermostat Housing Height Temperature Sensor

SP07 Thermostat Temperature Sensors

SP07 2-3/4 Inch (in) Thermostat Housing Height Temperature Sensor

SP07 Thermostat Temperature Sensors

SP07 2-3/4 Inch (in) Thermostat Housing Height Temperature Sensor

SP07 Thermostat Temperature Sensors

SP07 2-3/4 Inch (in) Thermostat Housing Height Temperature Sensor

SP07 Thermostat Temperature Sensors

SP07 2-3/4 Inch (in) Thermostat Housing Height Temperature Sensor
Description N/A The Pyromation thermostat temperature sensors are provided with the sensor, or the sensor and a (4 to 20) mA temperature transmitter, mounted on a sub plate within a standard size thermostat housing. The thermostat housing measures 2-3/4" h x 4-1/2" w x 1 5/8" d and can be mounted either horizontally or vertically on a 2" x 4" electrical hand box. The cover is vented on two sides to provide for airflow over the sensing element, regardless of mounting position. The standard temperature sensing elements are available as a fluoropolymer insulated thermocouple or a three-wire Resistance Temperature Detector (RTD). Matching transmitters are available for all configurations and output ranges.
Brands N/A Pyromation®
Configuration Code N/A SP07
Thermostat Housings N/A Thermostat housing with integral 100 O platinum RTD 0.00385 0ºC-1 temperature coefficient Class B N/A Thermostat housing with integral 100 O platinum RTD 0.00385 0ºC-1 temperature coefficient Class B N/A Thermostat housing with integral 100 O platinum RTD 0.00385 0ºC-1 temperature coefficient Class B N/A Thermostat housing with integral thermocouple element N/A Thermostat housing with integral thermocouple element
Options N/A (4-20) mA Resistance Temperature Detector (RTD) transmitter mounted in housing with sensor N/A 4-20 mA Isolated transmitter mounted in housing with sensor N/A (4 to 20) mA Isolated HART® head-mounted transmitter N/A (4-20) mA Resistance Temperature Detector (RTD) transmitter mounted in housing with sensor N/A 4-20 mA Isolated transmitter mounted in housing with sensor
Temperature Range N/A -40 to 85 ºC
Thermostat Housing Height N/A 2-3/4 in
Thermostat Housing Width N/A 4-1/2 in
Thermostat Housing Depth N/A 1-5/8 in