The assemblies listed below are designed for a broad range of applications that require resistance to corrosion and chemical attack. They provide very good temperature measurement and service life in plating, pickeling, and acid bath applications. The stainless steel sheath is coated with FEP and includes a fused FEP tip for excellent corrosion resistance.
Unit of Measure

Specifications

Brands

N/A Pyromation®

Configuration Code

N/A SP01
Thermocouple Types1 N/A Code - JJP Duplex (J Type) Code - JP Single (J Type) Code - KKP Duplex (K Type) Code - KP Single (K Type) Code - TP Single (T Type) Code - TTP Duplex (T Type)
Sheath Outer Diameter2 N/A Code (236)8 - 6 mm inCode 38 - 3/16 in. inCode 48 - 1/4 in. in

Measuring Junction

N/A Code GT - Grounded Code UT - Ungrounded

Sheath "X" Dimension

N/A Insert 3 Digit Sheath Length (X dimension) in Inches.

Sheath Mountings

N/A Code 00 - No fitting

Re-Adjustable Compression Fittings

N/A Code 56B - Fluorinated Ethylene Propylene Code 56C - Fluorinated Ethylene Propylene

National Pipe Thread (NPT) Size (Re-Adjustable Compression Fittings)

N/A Code 56B - 1/4 Code 56C - 1/2

Available Sheath Diameters (Re-Adjustable Compression Fittings)

N/A Code 10A - 3/16 inCode 10B - 1/4 inCode 10C - 1/4 inCode 56B - 1/4 inCode 56C - 1/4 in

Head Terminations

N/A Code 56CF63 (Not available with 3/16 in. O.D. sheath) - White polypropylene screw-cover head with FEP compression fitting holding head to sheath (Only available with 6mm OD sheath) Code 8HN63 - White polypropylene screw-cover head with 1/2 in. National Pipe Thread (NPT) stainless steel hex mounting fitting Code 9HP63 - White polypropylene screw-cover head with 1/2 in. National Pipe Thread (NPT) bushing holding head to sheath

Sheath Terminations for Head Terminations

N/A Code 4 - Standard plug Code 5 - Standard jack

Leadwire Transitions for Head Terminations

N/A Code 15 - Extension leadwire transition with relief spring Code 16 - Extension leadwire transition with heat-shrink tubing Code TT - Fluorinated Ethylene Propylene (FEP) coating: both sheath and leads (specify total length of Foam Polyethylene (FPE) coating) Example: TT(36)

Extension Leadwire

N/A Code T1 - Fluoropolymer insulation - solid conductor Code T3 - Fluoropolymer insulation - stranded conductor

Leadwire Terminations

N/A Code 0 - No termination Code 2 - 2 in. split leads, 1/4 in. stripped Code 3 - 2 in. split leads with spade lugs Code 4 - Standard plug Code 6 - Miniature plug

Options

Options

N/A MC - Mating connector RB - Rubber boot
  • 1 For grounded hot junctions substitute the letter 'G' in place of the 'U' above.