Brands |
N/A Pyromation® |
Configuration Code |
N/A SP-12 |
Sheath Diameter |
N/A Code 68 - 3/8 in |
Sheath Materials |
N/A 316 Stainless Steel |
Element Connection |
N/A Code 2 - 2 wire Code 3 - 3 wire Code 4 - 4 Wires |
Sheath Style |
N/A Code RHT - Replaceable Element |
Sheath Length |
N/A Code 05(1/2) - Hot Leg "A" Dimension (5(1/2) inch minimum hot leg and 6 inch minimum cold leg for RHT assembly) Code 06 - Cold Leg "B" Dimension (5(1/2) inch minimum hot leg and 6 inch minimum cold leg for RHT assembly) |
Radius Mounting Pad |
N/A Code 18RD - 1 in. wide x 2 in. long 18 Ga 304 Stainless Steel mounting pad with a 3/4 in. radius. Can be formed to fit pipe sizes from 1 in. National Pipe Thread (NPT) to 12 in. National Pipe Thread (NPT) |
Head Terminations |
N/A Code 31 - Aluminum Screw-Cover Head Code 34 - Cast Iron Screw-Cover Head Code 35T142A - (4-20) mA HART® Field transmitter with general-purpose aluminum housing Code 36T82-D10 - (4 to 20) mA dual input HART® transmitter with digital display and general-purpose aluminum housing with glass lid Code 37T-662A - (4 to 20) mA HART® Field Transmitter with general-purpose aluminum housing Code 49 - Flip-Top Aluminum Head Code 63 - (4 to 20) mA HART® field transmitter with aluminum explosion-proof housing, Group A Code 75T142C - (4 to 20) mA dual input HART® Field Transmitter with digital display and explosion-proof aluminum housing, Group A Code 76T82-D10 - (4 to 20) mA HART® Field Transmitter with dual cavity explosion-proof aluminum housing, Group A Code 77T82-D10 - (4 to 20) mA HART® Field Transmitter with dual cavity explosion-proof aluminum housing, Group A Code 91 - 316L Stainless Steel Screw-Cover Head Code 93 - Aluminum explosion-proof/flame-proof head, NEC, IEC, Atex approved Code 94 - 316L stainless steel explosion-proof/flame-proof head, NEC, IEC, Atex approved |
Note for Sheath Length |
N/A Specify 2 digit hot leg and 2 digit cold leg in in. |
Tolerance |
N/A Code N/A (Duplex) - Class B Code N/A (Duplex) - ClassA Code RAF185L (Single)- Class A Code RAF185M (Duplex) - ClassA Code RAF285L (Duplex) - Class A Code RBF185L (Single) - Class B Code RBF185M (Single) - Class B Code RBF285L (Duplex) - Class B |
Temperature Range |
N/A Code N/A (Duplex) - 50 to 450 ºCCode RAF185L (Single) - 50 to 200 ºCCode RAF185M (Single) - 50 to 450 ºCCode RAF285L (Duplex) - 50 to 200 ºCCode RBF185L (Single) - 50 to 200 ºCCode RBF185M (Single) - 50 to 450 ºCCode RBF285L (Duplex) - 50 to 200 ºC |
Options |
N/A D-2 - Class I Div. 2 Rating for option 31, 34, 91 I - Stainless Steel Tag NB - Nylon conduit reducer bushing SB - Steel conduit reducer bushing T31 - (4 to 20) mA Head-Mounted RTD Transmitter T71 - (4 to 20) mA Isolated Head-Mounted Transmitter T72 - (4 to 20) mA Isolated HART® Head-Mounted Transmitter T82-00 - (4 to 20) mA isolated HART® Dual Input Head-Mounted Transmitter |