Brands |
N/A Pyromation® |
Configuration Code |
N/A GP12 |
Sheath Diameter |
N/A Code 38 - 3/16 inCode 48 - 1/4 inCode 68 - 3/8 in |
Sheath Materials |
N/A 316 Stainless Steel |
Element Connection |
N/A Code 3 - 3 Wires Code 4 - 4 Wires |
Sheath Mounting Fittings |
N/A Code 00 - No fitting or bushing |
Leadwire Transitions |
N/A Code 15 - Extension leadwire transition with relief spring 204ºC Code 16 - Extension leadwire transition with heat-shrink tubing 104ºC Code 19 - Extension leadwire transition with no strain relief 204ºC |
Extension Leadwire "B" Dimension |
N/A Code T3A - Fluoropolymer insulation, stranded conductor, flexible armor (Insert 3 digit "B" length in inches.) Code T3P - Fluoropolymer insulation, stranded conductor, Polyvinyl Chloride (PVC) coated flexible armor (Insert 3 digit "B" length in inches.) Code T3T - Fluoropolymer insulation, stranded conductor, Fluorinated Ethylene Propylene (FEP) coated flexible armor (Insert 3 digit "B" length in inches.) |
Head Mounting Fittings |
N/A Code 8HN - 1/2" x 1/2" NPT Stainless Steel Hex Nipple Code 8RNDC - 1/2" x 3/4" National Pipe Thread (NPT) Stainless Steel Hex Nipple Code 9HP - 1/2" x 1/2" National Pipe Thread (NPT) Stainless Steel Bushing (No process threads) Code AG - Aluminum Cord Grip Code CG - Nylon Cord Grip |
Head Terminations |
N/A Code 31 - Aluminum Screw-Cover Head Code 34 - Cast Iron Screw-Cover Head Code 49 - Flip-Top Aluminum Head Code 63 - White Polypropylene Screw-Cover Head Code 91 - 316L Stainless Steel Screw-Cover Head |
Note for Sheath Length |
N/A Specify 3 digit "X" Length in inches |
Tolerance |
N/A Code R1T185H (Single) - Grade B (Tolerance) Code R1T185L (Single) - Grade B (Tolerance) Code R1T285H (Duplex) - Grade B (Tolerance) Code R1T285L (Duplex) - Grade B (Tolerance) Code R5T185L (Single) - (1/5) Class B (Tolerance) Code R5T285L (Duplex) - (1/5) Class B (Tolerance) Code RAF185L (Single) - Class A (Tolerance) Code RAF285L (Duplex) - Class A (Tolerance) Code RAT185H (Single) - Class A (Tolerance) Code RAT285H (Duplex) - Class A (Tolerance) Code RBF185L (Single) - Class B (Tolerance) Code RBF285L (Duplex) - Class B (Tolerance) |
Temperature Range |
N/A Code R1T185H (Single) - (-200 to 600) ºCCode R1T185L (Single) - (-200 to 200) ºCCode R1T285H (Duplex) - (-200 to 600) ºCCode R1T285L (Duplex) - (-200 to 200) ºCCode R5T185L (Single) - (-200 to 200) ºCCode R5T285L (Duplex) - (-200 to 200) ºCCode RAF185L (Single) -(-50 to 200) ºCCode RAF285L (Duplex) - (-50 to 200) ºCCode RAT185H (Single) - (-200 to 600) ºCCode RAT285H (Duplex) - (-200 to 600) ºCCode RBF185L (Single) - (-50 to 200) ºCCode RBF285L (Duplex) - (-50 to 200) ºC |
Compression Fitting |
N/A Code 05A - 316 Stainless Steel One-Time Adjustable Code 05B - 316 Stainless Steel One-Time Adjustable Code 05C - 316 Stainless Steel One-Time Adjustable Code 12A - 316 Stainless Steel Readjustable Code 12B - 316 Stainless Steel Readjustable Code 12C - 316 Stainless Steel Readjustable Code 19C - 303 Stainless Steel Spring-Loaded Well Fitting |
Thread Size |
N/A Code 05A - 1/8 inCode 05B - 1/4 inCode 05C - 1/2 inCode 12A - 1/8 inCode 12B - 1/4 inCode 12C - 1/2 inCode 19C - 1/2 in |
Options |
N/A Code I - Stainless Steel Tag Code SB - 1/2" NPT conduit reducer bushing Code T31 - (4 to 20) mA Head-Mounted RTD Transmitter Code T71 - (4 to 20) mA Isolated Head-Mounted Transmitter Code T72 - (4 to 20) mA Isolated HART® Head-Mounted Transmitter Code T82-00 - (4 to 20) mA isolated HART® Dual Input Head-Mounted Transmitter |