Explosion-Proof rated Heat-Tracing RTD assemblies are made for use in systems that measure the surface temperature of process pipe that is carrying products whose temperatures must be controlled to prevent freeze-up, or to maintain a viscosity level so that the inner medium will flow. They are intended for use in U.S. and Canadian hazardous areas and they are designed to extinguish flames inside the device, eliminating the potential for ignition of flammable mixtures in the surrounding atmosphere. FM and CSA certified assemblies, meet XP Class I Division I & II; Groups A, B, C, D; DIP Class II Division I; Groups E, F, G; Class III; Type 4/4X. These RTDs are offered in a variety of temperature ranges and are supplied with a 316SS sheath, and a 3/4" radius stainless steel mounting pad.
Unit of Measure

Specifications

Brands

N/A Pyromation®

Configuration Code

N/A XP07

Agency Approval

N/A Code XP - FM/CSA explosion-proof-certified assembly

100 Ohms Platinum Resistance Temperature Detector (RTD) Elements (α = 0.003 85 ºC-1)

N/A Code R1T185L - Single
Tolerance - Grade B
Temperature Range: -200 to 200 ºC

Code R5T185L - Single
Tolerance - (1/5) Class B
Temperature Range: -30 to 150 ºC

Code RBF185L - Single
Tolerance - Class B
Temperature Range: -50 to 200 ºC

Code RAF185L - Single
Tolerance - Class A
Temperature Range: -30 to 200 ºC

Code RBF185M - Single
Tolerance - Class B
Temperature Range: -50 to 482 ºC

Code R1T185H - Single
Tolerance - Grade B
Temperature Range: -200 to 600 ºC

Code RAT185H - Single
Tolerance - Class A
Temperature Range: -100 to 450 ºC

Code R1T285L - Duplex
Tolerance - Grade B
Temperature Range: -200 to 200 ºC

Code R5T285L - Duplex
Tolerance - (1/5) Class B
Temperature Range: -30 to 150 ºC

Code RBF285L - Duplex
Tolerance - Class B
Temperature Range: -50 to 200 ºC

Code RAF285L - Duplex
Tolerance - Class A
Temperature Range: -30 to 200 ºC

Code RBF285M - Duplex
Tolerance - Class B
Temperature Range: -50 to 482 ºC

Code R1T285H - Duplex
Tolerance - Grade B
Temperature Range: -200 to 600 ºC

Code RAT285H - Duplex
Tolerance - Class A
Temperature Range: -100 to 450 ºC

Sheath Diameter (316 Stainless Steel)

N/A Code 48 - 1/4 in. Code 68 - 3/8 in.

Element Connection

N/A Code 2 - 2-Wire
Code 3 - 3-Wire
Code 4 (Not available in duplex or with 440 Series Transmitter)- 4-Wire

Sheath Length

N/A Code 0304
Hot Leg - 3 in.
Cold Leg - 4 in.

Code 0306
Hot Leg - 3 in.
Cold Leg - 6 in.

Code 0308
Hot Leg - 3 in.
Cold Leg - 8 in.

Mounting Pad Material

N/A 304 Stainless Steel

Mounting Pad Width

N/A 1 in

Mounting Pad Length

N/A 2 in

Mounting Pad Thickness

N/A 18 gauge

Radius of Mounting Pad

N/A Code 18RD
Radius - 3/4 in.
NPT Pipe Size - 1-1/2 in.

Note for Mounting Pads

N/A Mounting pad is flexible enough to be formed around pipe sizes from 1 to 12" NPS pipe.

Standard Head Terminations

N/A Code 74 - DIN form B aluminum explosion-proof head
Code 75T-642B - (4 to 20) mA HART® field transmitter with aluminum explosion-proof housing
Code 76T82-D10 - (4 to 20) mA dual input HART® Field Transmitter with digital display and explosion-proof aluminum housing
Code 77T-662C - (4 to 20) mA HART® Field Transmitter with dual cavity explosion-proof aluminum housing
Code 93 - Aluminum explosion-proof head
Code 94 - 316L stainless steel explosion-proof head

Standard Head Options

N/A Code I - Stainless Steel Tag
Code SB - 1/2 in NPT Conduit Reducer Bushing
Code T-440 - 4 - 20 mA headmounted RTD transmitter (see instrument section)
T-441 - 4-20 mA isolated head-mounted transmitter (see instrument section)
T-442 - 4-20 mA HART® isolated headmounted transmitter see instrument section)
T82-00 - (4 to 20) mA dual input HART® head-mounted transmitter

Note

Note

N/A HART® is a registered trademark of HART® Communication Foundation.