COMPANY HEADER
Print Back
The standard insulated thermocouple extension wires generally available for base and noble metal thermocouple installations. By using the tabulated wire insulation data below, one can select a wire suitable for most process applications. When process conditions require the use of a special construction wire, please provide complete process requirements and specifications with your request for quotation. Minimums of 2,000 feet are generally required for special constructions.
Unit of Measure

Specifications

Brands

N/A Pyromation®

Materials

N/A Fluoropolymer

Single Conductor Insulation

N/A Ethylene Tetrafluoroethylene (ETFE) Extrusion, 0.008 in.

Single Conductor Impregnation

N/A None

Duplex Conductor Insulation

N/A Ethylene Tetrafluoroethylene (ETFE) 0.0010 in.

Duplex Conductor Impregnation

N/A None

Continuous Temperature Rating

N/A 150 ºC302 ºF

Temperature Rating (ASTM/ANSI SQL Reading)

N/A 200 ºC392 ºF

Color Code

N/A Yes

Abrasion Resistance

N/A Excellent

Moisture Resistance

N/A Excellent

Note for Temperature Rating

N/A Thermocouple extension grade wire is only calibrated up to 204 ºC (400 ºF)