Brands |
N/A Pyromation® |
Configuration Code |
N/A XP04 |
Agency Approval |
N/A Code XP - FM/CSA Explosion-proof Approved Assembly |
Thermocouple Type |
N/A Code E - Single Code EE - Duplex Code J - Single Code JJ - Duplex Code JJJ - Triplex Code K - Single Code KK - Duplex Code KKK - Triplex Code T - Single Code TT - Duplex |
Sheath Diameter |
N/A Code 4B - 1/4 in |
Sheath Materials |
N/A 316 Stainless Steel |
Measuring Junctions |
N/A Code U - Ungrounded |
Thermowell Selection |
N/A Select Thermowell from Thermowell Section. |
Element Options |
N/A Code SC - Self-contained spring-loaded element Code SL - Spring-loaded Element (Not available with option 75T, 76T, or 77T) |
Head Mounting Steel Fittings |
N/A Code 6HN - 1/2 in. x 1/2 in. NPT Hex Nipple 1" Length Code 6PN_ 1/2" NPT Pipe Nipple (Specify "E" Length in inches) Code 6XU_ (3 1/2" Minimum Length required / Maximum Allowable "E" Length is 9") - 1/2" NPT Union/Nipple (Specify "E" Length in inches) Code 8HN - 1/2 in. x 1/2 in. NPT Hex Nipple 1" Length Code 8PN - 1/2" NPT Pipe Nipple (Specify "E" Length in inches) Code 8XU_ (3 1/2" Minimum Length required / Maximum Allowable "E" Length is 9") - 1/2" NPT union/nipple (Specify "E" Length in inches) |
Head Mounting 316 Stainless Steel Fittings |
N/A Code 8HN - 1/2 in. x 1/2 in. NPT Hex Nipple 1" Length Code 8PN - 1/2" NPT Pipe Nipple (Specify "E" Length in inches) Code 8XU_ (3 1/2" Minimum Length required Maximum Allowable "E" Length is 9") - 1/2" NPT union/nipple (Specify "E" Length in inches) |
Head Terminations |
N/A Code 74 - DIN form B Aluminum Explosion-proof Head Code 75T142B - (4 to 20) mA HART® Field Transmitter with aluminum explosion-proof housing Code 76T82-D10 - (4 to 20) mA Dual Input HART® Field Transmitter with Digital Display and Housing Code 77T-662C - (4 to 20) mA HART® Field Transmitter with dual cavity explosion-proof aluminum housing Code 93 - Aluminum explosion-proof head Code 94 - 316L stainless steel explosion-proof head |
Certification |
N/A CSA (Canadian Standards Association) FM Approved |
Options |
N/A Code I - Stainless Steel Tag Code T71 - (4 to 20) mA Isolated Head-Mounted Transmitter Code T72 - (4 to 20) mA HART® isolated head-mounted transmitter Code T82-00 - (4 to 20) mA Dual input, isolated HART® head-mounted transmitter SB - 1/2" National Pipe Thread (NPT) conduit reducer bushing |