Items |
![]() 155 ServTex Insulator |
![]() 157 ServTex Insulator |
![]() 303 Fiberglass Insulator |
![]() 502 Polyvinyl Insulator |
![]() 503 Polyvinyl Insulator |
|||||
Description | N/A The standard insulated thermocouple extension wires generally available for base and noble metal thermocouple installations. By using the tabulated wire insulation data below, one can select a wire suitable for most process applications. When process conditions require the use of a special construction wire, please provide complete process requirements and specifications with your request for quotation. Minimums of 2,000 feet are generally required for special constructions. | |||||||||
Brands | N/A Pyromation® | |||||||||
Insulation Type | N/A ServTex | N/A ServTex | N/A | N/A | N/A | |||||
Materials | N/A Fiberglass | N/A Fiberglass | N/A Fiberglass | N/A Polyvinyl | N/A Polyvinyl | |||||
Single Conductor Insulation | N/A Heavy Fiberglass Braid Single Insulation | N/A Tetrafluoroethylene (TFE) Tape (not fused). Heavy Fiberglass Braid Single Insulation | N/A Enamel/Glass Braid 0.006 in. | N/A Polyvinyl Extrusion 0.012 in. to #20; #16 to 0.018 in. | N/A Polyvinyl Extrusion 0.015 in. | |||||
Single Conductor Impregnation | N/A Moisture Resistant Impregnation | N/A Modified Resin | N/A Modified Resin | N/A None | N/A None | |||||
Duplex Conductor Insulation | N/A ServTex Braid | N/A ServTex Braid | N/A Glass Braid 0.006 In. | N/A Polyvinyl Extrusion, 0.016 in. | N/A Twisted with Cotton Filler; Polyvinyl Chloride (PVC) 0.030 in. | |||||
Duplex Conductor Impregnation | N/A Ceramic-like Impregnation | N/A Moisture Resistant Compound | N/A Modified Resin | N/A None | N/A None | |||||
Continuous Temperature Rating | N/A 288 ºC550 ºF | N/A 288 ºC550 ºF | N/A 482 ºC900 ºF | N/A -29 to 105 ºC-20 to 221 ºF | N/A -29 to 105 ºC-20 to 221 ºF | |||||
Temperature Rating (ASTM/ANSI SQL Reading) | N/A 343 ºC650 ºF | N/A 343 ºC650 ºF | N/A 538 ºC650 ºF | N/A | N/A | |||||
Color Code | N/A Yes | |||||||||
Abrasion Resistance | N/A Good | |||||||||
Moisture Resistance | N/A Fair | N/A Fair | N/A Fair | N/A Excellent | N/A Excellent | |||||
Note | N/A Impregnation retained to 200 ºC (400 ºF) | N/A Impregnation retained to 204 ºC 400 ºF]: Tetrafluoroethylene (TFE) good to 260 ºC 500 ºF] | N/A Impregnation retained to (204 ºC 400 ºF) | N/A | N/A Stranded conductors only | |||||
Note for Temperature Rating | N/A Thermocouple extension grade wire is only calibrated up to 204 ºC (400 ºF) | |||||||||
|