COMPANY HEADER
Request Information
Remote-mounted thermocouple sensor assemblies are designed for applications where space is limited, or where high ambient temperatures or excessive heat conduction exists. They may also be a good choice for applications where high vibrations exist. They are available in a variety of thermocouple types, sheath diameters, sheath materials, process connections, and head options. These sensors can be mounted into a thermowell with the use of a spring-loaded well fitting, or directly into a process with a welded- or compression-style fitting. They are also available with a variety of optional head-mounted temperature transmitters.
Unit of Measure

Specifications

Brands

N/A Pyromation®

Configuration Code

N/A GP12

Thermocouple Types

N/A Code E - Single Code EE - Duplex Code J - Single Code JJ - Duplex Code K - Single Code KK - Duplex Code N - Single Code NN - Duplex Code T - Single Code TT - Duplex

Sheath Diameter

N/A Code 2 - 1/8 inCode 3 - 3/16 inCode 4 - 1/4 inCode 6 - 3/8 in

Sheath Materials

N/A Code 3 - Alloy 600 Code 8 - 316 Stainless steel

Available Sheath Types

N/A Code 3 - K Code 3 - N Code 8 - E Code 8 - J Code 8 - K Code 8 - T

Junction Type

N/A Code E - Exposed Code G - Grounded Code U - Ungrounded

Sheath Mounting Fittings

N/A Code 00 - No fitting or bushing

Compression Fitting

N/A Code 05A - 316 Stainless Steel One-Time Adjustable Code 05B - 316 Stainless Steel One-Time Adjustable Code 05C - 316 Stainless Steel One-Time Adjustable Code 12A - 316 Stainless Steel Readjustable Code 12B - 316 Stainless Steel Readjustable Code 12C - 316 Stainless Steel Readjustable Code 19C - 303 SS Spring-loaded well fitting

National Pipe Thread (NPT) Size

N/A Code 05A - 1/8 inCode 05B - 1/4 inCode 05C - 1/2 inCode 12A - 1/8 inCode 12B - 1/4 inCode 12C - 1/2 inCode 19C - 1/2 in

Leadwire Transitions

N/A Code 15 - Extension leadwire transition with relief spring 204 ºC Code 16 - Extension leadwire transition with heat-shrink tubing 104 ºC Code 19 - Extension leadwire transition with no strain relief 204 ºC

Extension Leadwire "B" Dimension

N/A Code T3A (Insert 3 digit "B" length in inches.) - Fluoropolymer Insulation, Stranded Conductor, Flexible Armor Code T3P (Insert 3 digit "B" length in inches.) - Fluoropolymer Insulation, Stranded Conductor, Polyvinyl Chloride (PVC) Coated Flexible Armor Code T3T (Insert 3 digit "B" length in inches. - Fluoropolymer Insulation, Stranded Conductor, Fluorinated Ethylene Propylene (FEP) Coated Flexible Armor

Head Mounting Fittings

N/A Code 8HN - 1/2" x 1/2" NPT Stainless Steel Hex Nipple Code 8RNDC - 1/2" x 3/4" NPT Stainless steel hex nipple Code 9HP - 1/2" x 1/2" NPT Stainless steel bushing (no process threads) Code AG - Aluminum Cord Grip Code CG - Nylon Cord Grip

Head Terminations

N/A Code 31 - Aluminum Screw-Cover Head Code 34 - Cast Iron Screw-Cover Head Code 49 - Flip-Top Aluminum Head Code 63 - White Polypropylene Screw-Cover Head Code 91 - 316L Stainless Steel (SS) screw-cover head

Note for Sheath Length

N/A Specify 3 digit "X" Length in inches

Options

Options

N/A Code I - Stainless Steel Tag Code SB - Steel conduit reducer bushing Code T71 - (4 to 20) mA Isolated Head-Mounted Transmitter Code T72 - (4 to 20) mA Isolated HART® Head-Mounted Transmitter Code T82-00 - (4 to 20) mA isolated HART® Dual Input Head-Mounted Transmitter