Brands
|
N/A
Pyromation®
|
Configuration Code
|
N/A
PL01
|
Thermocouple Types
|
N/A
Code JJP3 - Duplex Code JJP4 - Duplex Code JP2 - Single Code JP3 - Single Code JP4 - Single
|
Sheath Outer Diameter
|
N/A
Code JJP3 - 3/16 inCode JJP4 - 1/4 inCode JP2 - 1/8 inCode JP3 - 3/16 inCode JP4 - 1/4 in
|
Note for Other Element Types
|
N/A
For type E, K or T thermocouples, replace J in order code with required letter designation.
|
Bend Angle
|
N/A
Code 1 - Straight Code 2 - 45 Degree bend Code 3 - 90 Degree bend
|
"A" Dimension
|
N/A
Insert 2 digit "A" Length in inches (1 in. min). EX: 04 = 4 inch "A" Dimension.
|
Junction
|
N/A
Grounded junctions supplied as standard. Insert "U" only when requiring an ungrounded junction.
|
Sheath Fittings
|
N/A
Code 00 - No Fitting Code 01A - 1/8 in. National Pipe Thread (NPT) Stainless Steel (SS) One Time Adjustable Comp. Fitting Code 13A (13A are not available with 1/4 in. O.D. sheaths) - 7/16 in. I.D. Single Slot Spring-loaded Bayonet Fitting Code 15A - 1/8 in. National Pipe Thread (NPT) Brass One Time Adjustable Comp. Fitting Code 16A - Comp. Fitting With Bayonet Cap And Spring - 1/8 in. O.D. Sheaths Only (2-5/8 in. Min. 'a' Dimension)
|
Nominal Length
|
N/A
Code 01A - 1-1/4 inCode 13A (13A are not available with 1/4 in. O.D. sheaths) - 1-5/8 inCode 15A - 1-1/8 inCode 16A - 2-3/8 in
|
Extension Leadwire Type and "B" and "C" Dimension
|
N/A
000 - No leadwire, connector attached to sheath Code F1 - Fiberglass insulation - solid conductor Code F1A - Fiberglass insulation - solid conductor - flexible armor Code F1B - Fiberglass insulation - solid conductor - stainless steel overbraid Code F3 - Fiberglass insulation - stranded conductor Code F3A - Fiberglass insulation - stranded conductor - flexible armor Code F3B - Fiberglass insulation - stranded conductor - stainless steel overbraid Code T1 - Fluoropolymer insulation - solid conductor Code T1A - Fluoropolymer insulation - solid conductor - flexible armor Code T3 - Fluoropolymer insulation - stranded conductor Code T3A - Fluoropolymer insulation - stranded conductor - flexible armor
|
Note for Extension Leadwire
|
N/A
Insert 3 digit "B" length in inches. EX: F1036=36" "B" length; for assemblies requiring other than the standard 6" "C" dimension, insert 3 digit "C" length in inches after "B" dimension. EX: F1A036-012=36" "B " length with additional 12" leads beyond armo
|
Terminations
|
N/A
Code 0 - Leads not stripped Code 2 - 2 in. split leads, 1/4 in. stripped Code 3 - 2 in. split leads with spade lugs Code 4 - Standard plug Code 5 - Standard jack Code 6 - Miniature plug Code 7 - Miniature jack Code 8 - 2 in. split leads with 1/4 in. female disconnect lugs
|