Explosion-Proof, Fixed-Element Thermocouples are made for use in U.S. and Canadian hazardous areas. They are designed to extinguish flames inside the device, eliminating the potential for ignition of flammable mixtures in the surrounding atmosphere. CSA certified assemblies, dependent on connection head type, meet XP Class I Division I & II; Groups A, B, C, D; DIP Class II Division I; Groups E, F, G; Class III; IP66. They may be installed directly in the process without being inserted into a thermowell. The assemblies feature 316 stainless steel sheaths in various diameter sizes and ungrounded isolated junctions. They are available with or without process mountings and with aluminum or stainless steel explosionproof connection heads.
Unit of Measure

Specifications

Brands

N/A Pyromation®

Configuration Code

N/A XP02

Agency Approval

N/A Code XP - FM/CSA explosion-proof-certified assembly

Thermocouple Types

N/A Code E - Single
Code J - Single
Code K - Single
Code T - Single
Code N - Single
Code EE - Duplex
Code JJ - Duplex
Code KK - Duplex
Code TT - Duplex
Code NN - Duplex
Code JJJ - Triplex
Code KKK - Triplex

Sheath Diameters

N/A Code 2: 1/8 in.
Code 3: 3/16 in.
Code 4: 1/4 in.
Code 6: 3/8 in.

Sheath Materials

N/A Code 3 - Alloy 600
Standard Available Type - K

Code 4 - 310 Stainless steel
Standard Available Type - K

Code 5 - 446 Stainless steel
Standard Available Type - K

Code 8 - 316 Stainless steel
Standard Available Type - E, J, K, T

Measuring Junctions

N/A Code U - Ungrounded

'X' Dimension

N/A Insert three digit sheath length ("X" Dimension) in inches.

Sheath Mounting Fittings

N/A Code 00 - No Fitting

Head Mounting Fittings

N/A Code 6HN - 1/2 in. x 1/2 in. NPT steel hex nipple
8HN - 1/2 in. x 1/2 in. NPT stainless steel hex nipple
Code 9HP - 1/2 in. x 1/2 in. NPT Stainless steel bushing (no process threads)
Code 8RNDC - 1/2 in. x 3/4 in. NPT Stainless steel hex nipple

Head Terminations

N/A Code 74 - DIN form B aluminum explosion-proof head
Code 75T142B - (4 to 20) mA HART® Field Transmitter with aluminum explosion-proof housing
Code 76T82-D10 - (4 to 20) mA dual input HART® Field Transmitter with digital display and explosion-proof aluminum housing
Code 77T-662C - (4 to 20) mA HART® Field Transmitter with dual cavity explosion-proof aluminum housing
Code 93 - Aluminum explosion-proof head
Code 94 - 316L stainless steel explosion-proof head

Options

N/A Code SB - 1/2 in. NPT conduit reducer bushing
Code I - Stainless steel tag
Code T71 - (4 to 20) mA isolated head-mounted transmitter
Code T72 - (4 to 20) mA isolated Hart® head-mounted transmitter
Code T82-00 - (4 to 20) mA dual input, isolated HART® head-mounted transmitter

Note

Note

N/A HART® is a registered trademark of HART® Communication Foundation.