COMPANY HEADER
Request Information
Standard length spools are in 50 ft. increments. Non-standard lengths are available at an extra charge.
Unit of Measure

Specifications

Brands

N/A Pyromation®

Type

N/A Duplex - American Society for Testing and Materials (ASTM)/American National Standards Institute (ANSI) Type J

Color Code

N/A Negative Wire, Red; Positive Wire, White; Overall Brown, with Tracer Where Possible

Code

N/A J20 - 3 - S - 507

Wire Size

N/A 20 AWG

Conductor Type

N/A Stranded

Each Conductor Insulation

N/A Fluorinated Ethylene Propylene (FEP) Extruded

Outer Jacket Insulation

N/A Fluorinated Ethylene Propylene (FEP) extruded

Overall Insulation

N/A Stainless Over Braid

Limits of Error

N/A Standard

Nominal Size

N/A 0.092 x 0.144 in

Weight per 1000 Foot (ft)

N/A 15 lb

Thermocouple and Extension Wire Conductor Specifications

Solid Conductor Diameter

N/A Wire Gauge 14 - 0.0641 inWire Gauge 16 - 0.0508 inWire Gauge 20 - 0.0320 inWire Gauge 24 - 0.0201 inWire Gauge 28 - 0.0126 inWire Gauge 30 - 0.0100 in

Stranded Conductor Diameter

N/A Wire Gauge 16 - 0.0600 inWire Gauge 18 - 0.0490 inWire Gauge 20 - 0.0390 inWire Gauge 24 - 0.0250 in

Solid (Ohms) per Double Foot (ft)

N/A Wire Gauge 14 - 0.086 OWire Gauge 16 - 0.137 OWire Gauge 20 - 0.357 OWire Gauge 24 - 0.877 OWire Gauge 28 - 2.216 OWire Gauge 30 - 3.520 O

Stranded (Ohms) per Double Foot (ft)

N/A Wire Gauge 16 - 0.125 OWire Gauge 18 - 0.185 OWire Gauge 20 - 0.343 OWire Gauge 24 - 0.842 O