The Series 810 1/8 DIN Panel Indicator is loaded with standard and optional features that provide a flexible and economical solution for almost any application. Customize the unit with just the functions your application requires, minimizing your cost. Features flexible input/output options and large LED display. The digital indicator is fitted with one latchable relay as standard. Plug-in modules allow two additional relays, process variable retransmission, or transmitter power supply.
Unit of Measure

Specifications

Brands

N/A Pyromation®

Impedance for Thermocouple and Millivolts (mV) Ranges

N/A > 100

Impedance for Voltage (V) Ranges

N/A 47

Impedance for Milliampere (mA) Ranges

N/A 4.7

General

Total Output Configuration

N/A Up to 3

Maximum Output Configuration for Alarms

N/A 3

Maximum Output Configuration for Retransmit of PV

N/A 1

Maximum Output Configuration for Transmitter Power Supply

N/A 1

Alarm Types

N/A Direct Acting Process High Process Low Process Low Reverse and Logical OR

Human Interface

N/A 3 Button Operation 4 Digit 13 mm High Red Display Minimum and Maximum Indicators Plus Set-Up Alarm

PC Configuration

N/A Off-Line Configuration from Serial Port to Dedicated Configuration Socket

Output and Options

Alarms Relay(s)

N/A Contacts: Single Pole Double Throw (SPDT) 2 resistive at 240 V ac, > 500,000 operations, latching or non-latching
Retransmit Output1 N/A 0 to 20 mA4 to 20 mA0 to 10 V0 to 5 V
Typical Accuracy for Retransmit Output2 N/A ± 0.25 %
Direct Current (DC) Transmitter Power Supply3 N/A 20 to 28 V
Transmitter Power Supply (Nominal)4 N/A 24 V
Transmitter Power Supply for Maximum Load5 N/A 910 O

Inputs

Thermocouple Types

N/A B J K L N R S T

Resistance Temperature Detectors (RTD)

N/A 3-Wire Pt100 (a = 0.003 85 ºC-1), 50 O per Lead Maximum (Balanced)
Direct Current (DC) Linear6 N/A 0 to 20 mA0 to 50 mA10 to 50 mA4 to 20 mA0 to 10 V0 to 5 V1 to 5 V2 to 10 V

Accuracy

N/A ± 0.25% of Input Span ± 1 LSD (T/C CJC better than 0.7 ºC)
Approximately Sampling7 N/A 4 s

Sensor Break Detection

N/A < 2 second (except zero based Direct Current ((DC) ranges), High Alarms Activate (Low for Resistance Temperature Detectors (RTD), mA or V)

Operating Conditions

Temperature

N/A 0 to 55 ºC

Temperature for Storage

N/A - 20 to 80 ºC
Relative Humidity (RH)8 N/A 20 to 95 %

Power Supply

N/A 100 to 240 V

Power Supply (Alternating Current (AC))

N/A 7.5 V·A

Frequency

N/A 50 Hz60 Hz

Front Panel Protection

N/A IEC IP66 (Behind panel protection is IP20)

Approvals

C E Marked

N/A Unit complies with the legal requirements set forth by the EU regulations.

CULUS

N/A UL recognized component.

Features and Benefits

Features and Benefits

N/A
  • Four-digit LED display
  • Up To 3 Alarms
  • Transmitter power supply option
  • Min/Max value hold
  • Engineering units
  • PC configuration
  • Process variable retransmit option

Additional Information

Additional Information

N/A Each alarm has its own LED indicator for fast identification of alarms. Configuration can be modified in the field through the front panel or through use of a computer interface.
  • 1 into 500 O min
  • 2 into 500 O min
  • 3 22 mA at 20 V
  • 4 22 mA at 20 V
  • 5 22 mA at 20 V
  • 6 Scalable -1999 to 9999, decimal point available
  • 7 14 bit Resolution
  • 8 RH non-condensing